Fire Alarm Estimating

Device count from the code analysis and spacing rules rather than the reflected plan, with programming, acceptance testing and the interfaces to every other system.

Measured inCSI 28
EA
detectors, pulls, horns, strobes
LF
cable and raceway
LS
programming, testing, certification
Get a fixed quote within the hour

Scope

What we measure.

Measured from

Fire alarm plans, riser diagrams, sequence of operations and the fire alarm specification

  1. 01Initiating Devices
  2. 02Notification Appliances
  3. 03Control Panel & Power
  4. 04Cable & Raceway
  5. 05Programming & Test

Where bids go wrong

What other fire alarm estimates miss.

  1. Device count from the code analysis and spacing rules, not from the architectural reflected plan.

  2. Programming, acceptance testing and the authority-having-jurisdiction witness test.

  3. Interfaces to elevators, dampers, door holders and the sprinkler system.

  4. Monitoring, dialler and network connection required before occupancy.

Sample takeoff

How fire alarm line items come back.

Every quantity is traceable to the sheet it came from, in the units the trade buys in.

  • Quantities traced to the sheet they came from
  • Waste and productivity carried as visible lines
  • Formulas intact — edit any rate
estimate.xlsxFormulas on
Fire Alarm — sample takeoff
CSILine itemQuantity
28 31 00Initiating devices96 EA
28 31 00Notification appliances74 EA
28 31 11Control panel & power2 EA
28 05 13Cable & raceway4,200 LF
28 08 00Programming & test1 LS
Illustrative structure, not a real project. Every estimate is measured from your own drawings.

FAQ

Fire Alarm Estimating, answered.

Talk to an estimator

Not a salesperson. Same-day answers on working days.

+1 518 974 7222[email protected]
Do you count devices from the plans?

Yes. Initiating and notification devices are counted by type, with wire measured from the riser and device layout.

Are monitoring and testing included?

Acceptance testing and programming are measured. Ongoing monitoring is listed as an exclusion.

Can you use our cost book and labor rates?

Yes, and we prefer it. Your historical costs reflect your crews and your suppliers better than any published average. Send the template and we work inside it.

How does pricing work?

Pricing is per project and quoted before any work starts — no retainer, no minimum volume and no subscription.

Do you sign NDAs?

Yes. Drawings, specifications and pricing are treated as confidential by default, and we sign your NDA on request before any documents change hands.

Start a quote

Need fire alarm numbers for your next bid?

Pick your project type and send the drawings. We confirm the fee and delivery date within the hour on working days.